Views: 0 Author: Site Editor Publish Time: 2025-04-01 Origin: Site
Meta Description: Most butterfly valves close in 90° (¼ turn), but some require multiple rotations. Learn why and discover valves designed for fast, reliable shut-off.
Picture this: A chemical plant operator needs to urgently isolate a leaking pipeline. With seconds mattering, they grab the butterfly valve’s handwheel—but how many turns will it take? Too many, and the risk escalates.
The truth is: 90% of industrial butterfly valves close with just a 90° rotation (¼ turn). But exceptions exist. Let’s uncover why—and how to choose the right valve for your system.
Butterfly valves are quarter-turn valves, meaning a 90° rotation fully opens or closes them. This design uses a disc that swivels perpendicular to the flow (see diagram below).
Diagram: 90° rotation aligns the disc to block flow completely.
However, certain scenarios require multi-turn operation:
High-pressure systems (e.g., oil & gas): 2-4 turns for precise control.
Gear-operated valves: 10+ turns for large-diameter pipes (DN300+).
Pro Tip: Check the valve's nameplate to confirm turns needed.
Eccentric Disc Design (Standard):
90° shut-off. Common in water treatment, HVAC.
Example: Our HK60-D-GF Electric Hard Seal Flanged Butterfly Valve uses a triple-offset disc for zero friction during rotation.
Gear Operators (Multi-Turn):
Reduces manual effort for large valves (DN200+).
Higher pressure = tighter sealing = slower operation.
Valve Size (DN) | Pressure Rating | Turns to Close |
---|---|---|
50 | 150 PSI | 0.25 |
200 | 300 PSI | 2 |
400 | 600 PSI | 15 (gear) |
3. Seal Material
Soft Seals (EPDM/NBR): Quick 90° closure. Ideal for water.
Metal Seals (Stainless Steel): Require slow rotation to prevent wear. Used in steam systems.
If your standard valve resists closing:
Lubricate the Stem: Use high-temp grease.
Check for Debris: Particles jam the disc.
Inspect the Seal: Worn seals cause leaks.
Emergency? Contact our 24/7 support team.
A: Due to differences in internal mechanisms (e.g., stem design, sealing methods), direct conversion is not possible. However, you can:
Inspect the existing valve: Check for insufficient lubrication or worn components .
Install a compatible actuator: Certain electric/pneumatic actuators may reduce operation time (consult an engineer for compatibility).
A: Common causes and fixes:
Insufficient lubrication:
Clean the valve stem with high-temperature grease (silicone- or lithium-based).
Avoid machine oil (attracts dust).
Misalignment:
Ensure pipeline alignment and evenly tightened flange bolts.
Pipe distortion can cause disc-body friction.
High system pressure:
Opt for valves with bearing support to reduce rotational resistance.
A: Industry benchmarks (manual operation):
Small valves (DN50-DN100): 1-3 seconds (quarter-turn design).
Medium/large valves (DN150-DN300):
Gear-operated: 10-30 seconds (~2 seconds per turn).
If slower, inspect gearbox lubrication or stem alignment.
A: Quick identification methods:
Visual labels:
Look for "Quarter-Turn" or "90° Operation" markings on the valve/handwheel.
No label? Test rotation: Smooth 90° movement indicates quarter-turn.
Technical documentation:
Check the model’s manual (often available on the manufacturer’s website).
A: Possible factors:
Incomplete closure:
Ensure full rotation (listen for a "click" or check stop positions).
Multi-turn valves require reaching specified turns (refer to stem markings).
Seal damage:
Over-rotation wears soft seals (EPDM/NBR).
Self-test: Open/close the valve 3 times. Persistent leaks mean seal replacement.
A: Causes include material contraction or frozen lubricant:
Emergency fix:
Wrap the valve with insulation or apply anti-freeze releasing spray (never use open flames!).
Long-term solution:
Use low-temperature valves (e.g., stainless steel stems + PTFE seals).
Switch to cold-resistant lubricants (functional at -40°C).
Faster Closing: Patented bearing systems reduce rotation resistance (ISO 9001 certified).
Longer Lifespan: Laser-hardened stems withstand 100,000+ cycles.
24/7 Support: Get replacement parts or on-site help within 12 hours.
Ready to Upgrade?
→ Download COVNA valve catalog